13.0 TROUBLESHOOTING TABLE

Possible troubles which might occur to the accessory are listed below. The manufacturer disclaims all
responsibility for damages to people, animals or objects due to improper operation by non-unauthorised
personnel. In case of trouble, call Technical Service Department for instructions on how to service and/or
adjust the machine in full safety to avoid any risk of damage to people, animals or objects.
In an emergency and before maintenance on tyre-changer, set the main switch to "0" (placed on the tyre-changer
where the accessory is mounted) and lock it in this position.
Problem
No movement is produced when
the control pedal is operated.
When the machine is aired, the lift-
ing device tends to move, with no
consent by the operator.

14.0 TECHNICAL DATA

Wheel maximum weight: .................................80 Kg
Operating pressure: ................................. 8 - 10 bar
Lifting device weight: .......................................20 Kg

15.0 STORING

If the machine is to be out of use for a long time, dis-
connect the power supply and protect the lifting device
from dust's deposit.
INSTRUCTIONS FOR
ASSEMBLY AND USE
CONTACT AUTHORIZED TECHNICAL SERVICE
do not try and service alone
Possible cause
1. Supply missing or insufficient.
2. The supply pipes have not been
correctly assembled.
3. The control valve is not working.
When the lifting device is fixed to
the machine, the spool that con-
nects the pedal to the valve has lost
its settings.

16.0 SCRAPPING

When the decision is taken not to make further use
of this device, it is advisable to make it inoperative by
removing the connection pressure hoses.
The device is to be considered as special waste and
should be dismantled into homogeneous parts.
Dispose of it in accordance with current legislation.

17.0 FUNCTIONAL DIAGRAMS

The following list reports the device and the exploded
components.
Remedy
1. Check supply.
2. Check pipes fitting.
3. Call for technical as-
sistance.
Re-calibrate the control valve rod
slackening the nut between the rod
and the fork and turn the rod in cw
or ccw direction until restoring the
correct functioning.
ANY DAMAGE RESULTING FROM
FAILURE TO FOLLOW THE IN-
STRUCTIONS MENTIONED ABOVE
WILL RELEASE THE MANUFAC-
TURER FROM ANY LIABILITY AND
MIGHT CAUSE THE LOSS OF THE
WARRANTY CONDITIONS!

Advertisement

Table of Contents
loading

This manual is also suitable for:

G800a121np

Table of Contents