7. Troubleshooting

7-1 Self - diagnostic Functions (Buzzer Alarm)
NO
ERROR
In case DOOR is opened during the
LID OPEN
1
ERROR
intermittent or ordinary dehydration.
-In case 3-times UNBALANCE are sensed
UNBALANCE
2
ERROR
during the dehydration in the cycle.
In cases water feed won't reach the
selected water level in 60 min, and no
WATER FEED
3
change of frequency is observed. (the
ERROR
functions of Rinse and UNBALANCE
Release included)
In case the water level won't lower below
4
the RESET level in 15 min since the
DRAIN ERROR
drain started
In case the water-level frequency higher
WATER LEVEL
5
than 30.0KHZ or lower than 15.0KHZ
SENSOR
S/W POOR
appear longer than 5 sec.
CONDITION
17
BUZZER
DISPLAY
0.5sec ON/OFF
dE
Sounding
5 times
0.5sec ON/OFF
Sounding
UE
5 times
0.5sec ON/OFF
Sounding
4E
5 times
0.5sec ON/OFF
Sounding
5E
5 times
0.5sec ON/OFF
Sounding
1E
5 times
SOLUTION
Press POWER KEY
and close DOOR.
Press POWER KEY
and open DOOR.
Press POWER KEY
and START KEY.
Press POWER KEY
and START KEY.
Press POWER KEY.

Hide quick links: