MEMORY FEATURE
The memory feature will work as follows:
Dipswitch set to "Memory Off" – Will result in a lube cycle each
time power is turned on. Lube cycle will start at the beginning
of the on time setting.
Dipswitch set to "Memory On"
1.
Power is turned off during the off time (time between lube
cycles). When turning power back on will cause the lube
cycle to continue from the point of interruption.
2.
Power is turned off during the on time or pumping time.
Turning power back on will cause the lube cycle to start at
the beginning of the on time setting.
Electrical Shock Hazzard.
Turn off and lock out power
before opening enclosure.
Form 403569
CENTRO-MATIC
Controller Components and Setting the
Dipswitch Identification - See Illustration 1
30 seconds or 10 seconds - Select the maximum amount of
Timer or Controller -
Hours or Minutes -
Memory Off or Memory On - Select memory feature.
Off Time Switch - See Illustration 1
Using the Rotary Switch you can select .5, 1, 2, 4, 8, 15, 24
or 30. The units are either minutes or hours as determined by
the dipswitch setting.
Enclosure Cover - See Illustration 1
Green LED -
Green LED -
Red LED -
Manual Lube -
Illustration 1
4.1A-68020-E05
Controller
"On Time".
Select Timer Mode or
Controller Mode.
Select the unit for the "Off Time"
Rotary Switch.
Indicates that power is applied to the
controller.
Indicates that the pump is on.
Indicates an alarm condition.
Pressing will initiate a lube cycle.