Replacement Of Contact Nipple And Ceramic Washer - BAC EASYBOND MK2 Operation And Maintenance Manual

Table of Contents

Advertisement

12.2.3 REPLACEMENT OF CONTACT NIPPLE AND CERAMIC WASHER

This section can also be used for the removal/replacement of ferrule holder
pin holder
(5)
Figure 15 Sequence
(numbers in brackets are from
1. Unscrew by hand the ferrule holder
2.
Place allen key
(31)
front centre piece
to allow removal of the pin holder
3. Unscrew by the pin holder (5).
4. Remove plastic spark shield
5. Remove ceramic washer
6.
Using the peg spanner
should be a tight fit and screwed down fully. The nipple should be flush or no more than
0.2mm below the front face. Replace the ceramic washer at the same time
When re-installing the plastic spark shield
seated onto the three legs of the pin holder
Reassemble using reverse procedure and removing allen key before replacing the ferrule holder
by hand, lightly grease the thread on the to avoid cross threading. .
BAC Document Number: Easybond MKII Manual V03
and plastic spark shield
(1).
in the hole of the front piece silver locking ring
(10)
(turn pin holder if necessary). This will lock in place the centre piece
(5).
(6).
(8).
(29)
remove and replace the new contact nipple
(6)
Figure 15
(6)
Figure
13):
ensure that the three indentations are correctly
(5).
28/08/13
(7)
(1),
(2)
and the hole in the
(9).
The nipple
(8).
Page 27 of 32

Advertisement

Table of Contents
loading

This manual is also suitable for:

273 199 5660