12.2 ROUTINE MAINTENANCE

12.2.1 SERVICE SCHEDULE

(numbers in brackets are from
Daily
1. Check the cable
(27)
2. Check that the pin and ferrule holders are undamaged and hold the brazing pin and ferrule
centrally and securely.
Weekly
1. Check and clean the contacts

12.2.2 REPLACEMENT OF THE CONTACT SET

Figure 14 Sequence
(numbers in brackets are from
Dismantling the contact set
Open the gun handle plate using the provided allen key
1. Unscrew the flat contact with the spanner
spring washer is removed.
2. Unscrew the domed contact and remove from the contact arm (25), ensure the spring
washer is removed.
Re-assembly
1. Screw the domed contact into the spring bracket (23). Ensure that the spring washer is
located correctly in the groove in the contact before tightening.
Do not over tighten the contacts.
2. Place the flat contact through the hole in the gun cable lug
location. Use the screwdriver between both contacts to assist with tightening.
Do not over tighten the contacts. Replace gun handle plate and screws.
BAC Document Number: Easybond MKII Manual V03
Figure
13)
to the battery unit is undamaged.
(26)
using emery cloth.
(26)
Figure 14
Figure 14
Figure
13)
(31)
to remove screws.
(30)
and remove the gun cable (27), ensure the
(27)
28/08/13
and offer both up to the
Page 26 of 32