BAC EASYBOND MK2 Operation And Maintenance Manual page 22

Table of Contents

Advertisement

Battery too low to recover =
start to charge
4
Stage four: Deeply Discharged Battery Recovery Mode
Battery in recovery mode soft start =
5
Stage five: Main Bulk Charge
Battery in bulk charge = Solid yellow
6
Stage six: Proportional Timing Optimisation Charge
Battery in last bulk charge, 80% charged = Yellow flash.
7
Stage seven: Fully Charged Float Maintenance
Battery full = Solid Green.
8
Stage eight: Fail To Charge Safety Time Out
Battery failed to charge =
Should the charger detect a faulty battery it will flash red instead of holding solid green during
the float charge stage.
EIGHT-STEP CHARGE PROFILE
The battery will not be fully charged when the charger switches from absorption to float. The
battery will need a minimum of 16-24 hours on float charge before it is fully charged. The battery
can be used as soon as it enters float charge, however repeatedly cycling without the necessary
16-24 hours on float will cause premature failure and reduce the life of the batteries.
BAC Document Number: Easybond MKII Manual V03
Red
Charge
flash. Rapid twice per second charger will not
Red
Charge
Red flash
slow flash (on for two seconds off for one).
Figure 11
Yellow flash alternate.
28/08/13
Page 22 of 32