02. Precautions for product design

02-1. Considerations in mechanical design
1) Prevention of problems during use
(1)The connectors have a simple locking structure, but make sure to consider
preventive measures against the detachment of mated connectors during
practical use.
Casing
Sub-board
(flexible board)
- Make sure to eliminate any gaps between the casing and board.
- We recommend that the holding force is set greater than the insertion force of
the connector.
- Select an appropriate cushioning material with a suitable shape and dimensions,
and hold down the
center, it may cause detachment of mated connectors.)