Olimpia splendid SECCOPROF 30 P Instructions For Installation, Use And Maintenance Manual

Olimpia splendid SECCOPROF 30 P Instructions For Installation, Use And Maintenance Manual

Hide thumbs Also See for SECCOPROF 30 P:

Advertisement

Quick Links

SECCOPROF 30 P
SECCOPROF 40 P
EN
INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE
Attenzione: Rischio di incendio
Caution: Risk of fire
Attention : Risque d'incendie
Achtung: Brandrisiko
Atención: Riesgo de incendio

Advertisement

Table of Contents
loading

Summary of Contents for Olimpia splendid SECCOPROF 30 P

  • Page 1 SECCOPROF 30 P SECCOPROF 40 P INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE Attenzione: Rischio di incendio Caution: Risk of fire Attention : Risque d'incendie Achtung: Brandrisiko Atención: Riesgo de incendio...
  • Page 3 1. The appliance contains R290 gas (A3 flammability classification) 2. The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation. The appliance must be installed, used and stored in a room with a floor surface in compliance with the minimum sizes indicated in the chart at page 9. This appliance contains a quantity of refrigerant gas R290 equal to the one indicated in the data label located on the appliance. 3. This a ppliance c an b e u sed b y c hildren a ged f rom 8 y ears a nd a bove a nd p erson w ith r educed p hysical, s ensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. (be...
  • Page 4 30cm 20cm 20cm m i n . 7 0 c m min. 2m min. 2m...
  • Page 6 PAGE INTENTIONALLY LEFT BLANK...
  • Page 7: Table Of Contents

    MAIN INDEX 0 - WARNINGS ..........................2 0.1 - GENERAL INFORMATION ......................2 0.2 - SYMBOLS ............................2 0.2.1 - Editorial pictograms .........................2 0.3 - GENERAL WARNINGS ........................4 0.4 - PROPER USE ..........................8 0.5 - UNINTENDED AND POTENTIALLY DANGEROUS USE ...............8 0.6 - WARNINGS FOR R290 REFRIGERANT GAS ................9 1 - DESCRIPTION OF THE APPLIANCE ..................
  • Page 8: Warnings

    ILLUSTRATIONS The illustrations are grouped on the initial pages of the manual MAIN INDEX The main index of this manual is given on page “EN-1” 0 - WARNINGS 0.1 - GENERAL INFORMATION First of all, we would like to thank you for choosing our appliance. 0.2 - SYMBOLS The pictograms in the next chapter provide the necessary information for correct, safe use of the machine in a rapid, unmistakable way.
  • Page 9 DANGER OF HIGH VOLTAGE Signals to the personnel that the operation described could cause electrocution if not performed according to the safety rules. GENERIC DANGER It informs the personnel concerned that if the operation is not carried out in compliance with the safety regulations, it presents the risk of suffering physical damage.
  • Page 10: General Warnings

    1. This document is restricted in use to the terms of the law and may not be copied or transferred to third parties without the express authorization of the manufacturer, OLIMPIA SPLENDID. Our machines are subject to change and some parts may appear different from the ones shown here, without this affecting the text of the manual in any way.
  • Page 11 Safety Regulations in force in the country of installation. 11. In case of replacement of parts, use only original OLIMPIA SPLENDID parts. 12. If the unit is unused for a long period, or no-one uses the climate-controlled room, it is recommended to disconnect the electric power supply in order to prevent accidents.
  • Page 12 22. If the appliance’s plug is incompatible with the socket, have the socket replaced with a suitable one by a qualified technician, who must ascertain that the section of the socket cables is compatible with the power absorbed by the appliance. We do not recommend using adaptors and/or extension cables.
  • Page 13 39. Unplug the cord when unit is not in use for an extended period of time and/ or when no one is home. 40. Do not use the appliance outdoors or on wet surfaces. Avoid dropping liquids on the appliance. Do not use the appliance near sinks and taps. 41.
  • Page 14: Proper Use

    • This appliance is only intended for a domestic use or similar. • An improper use of the appliance with possible damages caused to people, things or animals releases OLIMPIA SPLENDID from any responsibility. 0.5 - UNINTENDED AND POTENTIALLY DANGEROUS USE •...
  • Page 15: Warnings For R290 Refrigerant Gas

    0.6 - WARNINGS FOR R290 REFRIGERANT GAS 1. THE APPLIANCE CONTAINS R290 GAS (FLAMMABILITY CLASSIFICATION A3). 2. THE APPLIANCE SHALL BE STORED IN A WELL-VENTILATED AREA WHERE THE ROOM SIZE CORRESPONDS TO THE ROOM AREA AS SPEC- IFIED FOR OPERATION. 3.
  • Page 16 17. TRANSPORT OF EqUIPMENT CONTAINING FLAMMABLE REFRIGERANTS See transport regulations. 18. MARKING OF EqUIPMENT USING SIGNS See local regulations. 19. DISPOSAL OF EqUIPMENT USING FLAMMABLE REFRIGERANTS See national regulations. 20. Storage of equIpment/applIanceS The storage of equipment should be in accordance with the manufacturer’s instructions.
  • Page 17 exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space.
  • Page 18 23. REPAIRS TO SEALED COMPONENTS a) During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
  • Page 19 Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25 % maximum) is confirmed. leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work. If a leak is suspected, all naked flames shall be removed/ extinguished.
  • Page 20 30. DECOMMISSIONING Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant.
  • Page 21 31. LABELLING Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant. 32. RECOVERY When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely.
  • Page 22: Description Of The Appliance

    1 - DESCRIPTION OF THE APPLIANCE 1.1 - FEATURES The appliance is packaged singularly in a cardboard packaging. Store the packaging in vertical position. the dehumidifier powerfully removes moisture from the air to decrease the humidity level of the room and keep the indoor air dry and comfortable. It is possible to select the desired level of humidity by means of the digital humidistat. Thanks to the timer, it is possible to set the automatic switching on and off of the appliance.
  • Page 23: Installation Of The Appliance

    1.3 - INSTALLATION OF THE APPLIANCE • after removing the packaging, check that the appliance is in perfect condition; in case of doubts do not use it and refer to professionally qualified personnel. • Install the appliance on a rigid and levelled floor while keeping the room ventilated. • place the appliance in a suitable environment. make sure that curtains or other objects don-t obstruct the air flow (fig. 5). • leave at least 20cm of free space on both sides and behind the appliance and leave at least 30cm of free space above it (Fig. 1). • remove the tank (7) and uncoil the supply cord (9). • Correctly reposition the tank (7) in the appliance body. • Insert the plug in the power socket; the appliance emits a “beep”. 1.4 - CONTROL PANEL ON/OFF key Press this key to start the appliance.
  • Page 24 Timer key With the appliance electrically powered but not running press the key “TIMER” to enter the function, then press the key “TIMER” several times to set the delay time of switching on (from 1 to 24 hours), the led TIMER lights up in green. When the value set on the display stops flashing, the value is saved and the led switches steady on.
  • Page 25: Blackout

    Fan key Press this key when the appliance is running to select the desired fan speed. - Maximum speed - Led turned on in green - Minimum speed - Led turned on in green It is not possible to change the fan speed in “LAUNDRY” mode. Mode key Press this key when the appliance is running to select the desired function.
  • Page 26: Installation

    2 - INSTALLATION 2.1 - APPLIANCE TRANSPORT • Transport and handling of the appliance must be carried out in vertical po- sition. If it is transported in a horizontal position, wait at least one hour before starting it. • Before moving or transporting the appliance, completely drain condensation by working as described in paragraph 3.1.a CAUTION Transporting the appliance on delicate floors (for instance: wooden floors):...
  • Page 27: Electrical Connection

    2.3 - ELECTRICAL CONNECTION the appliance is fitted with a power cable with plug. Before connecting the appliance, make sure that: • the voltage and power frequency values match those specified on the appliance plate data. • the power supply line is equipped with an efficient ground connection and that it is correctly dimensioned for the maximum absorption of the appliance. • The appliance’s power network must be equipped with a suitable omnipolar disconnection device compliant with national installation regulations.
  • Page 28: Maintenance And Cleaning

    4 - MAINTENANCE AND CLEANING Before performing any cleaning or maintenance intervention on the appliance, disconnect the plug from the power socket and wait for the fan to stop completely. 4.1 - CLEANING 4.1.a - Cleaning the appliance • use a dry cloth to clean the appliance. • If the appliance is very dirty, it is possible to use a cloth dampened with warm water (max 50°c) and a mild detergent to clean its external parts.
  • Page 29: Tank Cleaning

    • Store in a fresh and dry place away from humidity. 6 - TECHNICAL DATA Consult the rating plate applied to the product (Fig. 2) and the technical data listed below: SECCOPROF 30 P SECCOPROF 40 P Rated Capacity 30l / day (30°c, 80%rH) 40l / day (30°c, 80%rH)
  • Page 30: Trouble Shooting

    7 - TROUBLE SHOOTING BEFORE CALLING FOR SERVICE Before contacting professional service, consult this list. This list includes common occurrences that are not the result of a defect in workmanship or materials. PROBLEM POSSIBLE CAUSES ADVISED SOLUTIONS The supply cord is disconnected Insert the plug in the power socket and make sure there’s electrical voltage The tank full warning led is turned on...
  • Page 32 Australia and New Zealand headquarters Olimpia Splendid Australia Pty Ltd 80-84 Burlington Street, Oakleigh VIC 3166 Phone (03) 9563 2778 olimpiasplendid.com.au The technical data and the aesthetic characteristics of the products may undergo changes. Olimpia Splendid reserves the right to modify them at any time...

This manual is also suitable for:

Seccoprof 40 p

Table of Contents