Fitting The Lower Thermal Insulation Mat; Fitting The Thermal Insulation Jacket - Viessmann VITOCELL 140-E Installation And Service Instructions Manual

Solar buffer cylinder
Table of Contents

Advertisement

Installation sequence
Vitocell with fitted Solar-Divicon
1.
A
C
3.
B
2.
Fig. 22
1. Connect heating water flow connection pipe
connection
on the Vitotrans.
D
2. Connect heating water return connection pipe
connection
on the Vitotrans.
E

Fitting the lower thermal insulation mat

!
Please note
The thermal insulation must not come into con-
tact with naked flames.
Exercise caution when welding and brazing.
Fig. 23

Fitting the thermal insulation jacket

!
Please note
The thermal insulation must not come into con-
tact with naked flames.
Exercise caution when welding and brazing.
24
(cont.)
4.
DE F
to
3. Connect heating water stratification connection pipe
A
4. Connect the pipes to the cylinder connections.
B
to
Note
Only carry out the following steps if the tightness test
(see page 20) was successful.
to connection
on the Vitotrans.
C
F