Technical data:
Trade name
Art. No.:
Performance data operation with logs
Nominal heat output [kW]
Max. log length [m]
Firebox volume [l]
Burner efficiency rate [%]
Average exhaust gas temperature [°C]
Performance data automatic operation (chippings)
Maximum nominal heat output [kW]
Minimum nominal heat output [kW]
Burner efficiency rate at nominal load [%]
Electrical connections, total [kW]
Electrical power, ignition device [kW]
Electrical power, exhaust fan [kW]
Electrical power, feed auger [kW] 3 x 400V
Electrical power, de-ashing and cleaning [kW]
Electrical power consumption at max. nominal load [kW]
Electrical power consumption at min. nominal load [kW]
Exhaust gas mass flow, nominal heat output [g/s]
Average exhaust gas temperature at maximum nominal load, °C
Average exhaust gas temperature at minimum nominal load, °C
Maximum water content, forest wood chips [W %]
Maximum chip size
Heating-relevant specs
Volume on heating gas side [litres]
Volume of ash pan (logs/automatic) [litres]
Max. flue draught, wood [Pa]
Chimney draught required [Pa]
Water-bearing resistance (Diff. 10 K) [mbar]
Boiler water volume [l]
Boiler weight without water [kg]
Test pressure [bar]
Maximum operating pressure [bar]
Maximum boiler temperature [°C]
Minimum return temperature [°C]
Thermic safety outlet: min. flow rate at 2.5 bar [kg/h]
Burner group
Burner pump, Grundfos model
Electrical power for pump [W]
Pump output m³/h at mWS
Burner control valve, Siemens model
Drive for burner control valve, Siemens
Weight of burner group [kg]
1)
For function, from W 25 reduction of burner output
2)
Maximum overpressure during the start-up phase (chimney cold) in the exhaust pipe after the exhaust blower
3)
Do not install a chimney draught controller!
1
Köb Holzheizsysteme GmbH, Flotzbachstr. 33, A-6922 Wolfurt, Tel. +43/5574/6770-0, Fax 65707, E-Mail: office@kob.cc
Spec Sheet
Burner System Loader System
PYROMAT-DYN
1)
2)
3)
Subject to technical changes
Boiler PYROMAT-DYN..
45
65
KPM-DYN-45
KPM-DYN-65
7387408
7387860
49
75
0.5
0.5
185
255
91.7
91.5
146
145
35
52
10
15
92.4
92.3
1.91
1.91
1.6
1.6
0.08
0.08
0.12
0.12
0.07
0.07
0.1
0.2
0.04
0.05
35
56
138
136
79
78
W35
W35
G50
G50
170
180
14 / 34
18 / 43
25
25
+-0
+-0
8
16
130
170
760
935
5
5
3
3
100
100
70
70
2000
2800
RS 30/6
TOP-S 30/7
49-93
85-195
2.5 at 6.5
7.5 at 7.0
VXG 48.32
VXG 48.32
SQS 35.00
SQS 35.00
14
16
3010-3
2009-03-01_GB
85
KPM-DYN-85
7388033
100
0.5
255
91.3
144
70
20
92.3
1.91
1.6
0.15
0.12
0.07
0.3
0.06
68
134
77
W35
G50
190
18 / 43
25
+-0
25
210
1065
5
3
100
70
3500
TOP-S 30/7
85-195
7.5 at 7.0
VXG 48.40
SQS 35.00
20