Step
3
Heat up the brazed part
of the suction side and
disconnect it.
Lift the compressor up
4
and remove it.
Removal Procedure
Procedure
Suction side
Removal of Compressor
Points
Note:
Never use a metal saw to
cut pipes because the
sawdust may enter the
circuit.
When withdrawing the
pipes, be careful not to
pinch them firmly with pliers.
The pipes may get
deformed.
Provide a protective sheet or
a steel plate so that the
(R12032)
brazing flame cannot
influence peripheries.
Be careful so as not to burn
the compressor terminals,
the name plate, the heat
exchanger fins.