Download Print this page

Daikin RKS09HV2S Service Manual page 10

2.0/2.5/3.5 kw class 9000/12000 btu/h class

Advertisement

Removal of Outer Panels / Fan Motor
Step
8
Open the 2 hooks and
release the fan motor
lead wire.
9
Remove the 4 screws
and remove the fan
motor.
4. Remove the right side
panel.
Remove the 2 screws
1
on the rear side.
8
Procedure
Fan motor
Points
When reassembling, put the
fan motor lead wire through
the back of the fan motor so
as not to be entangled with
the outdoor fan.
(R11835)
Lead wire
(R12311)
(R12162)
Si001156
Outdoor fan
(R3249)
Removal Procedure

Advertisement

loading