Si001156
Step
4
Pull out the forced
operation button PCB.
Disconnect the
connector [S110] to
remove the forced
operation button PCB.
Disconnect the
5
selective connector for
standby electricity
saving and pull out the
relay connector.
Cut the clamp.
6
Removal Procedure
Procedure
Forced operation button PCB
Be careful of a sharp
protrusion at the back of the
forced operation button
PCB.
[S110]
(R13742)
Relay
connector
Selective connector
(R13507)
(R11858)
Removal of PCBs
Points
15