There are 10 pages in this OSD, the ways to enter factory OSD are open user OSD, then
press power on button. If you have to return user OSD, open factory OSD and press power
on button again.
Go to \User OSD\Environment\lamp hours\minutes, then press Right, Left, Right, Left,
Enter in a row to switch to factory OSD.
1.
Factory
This page is mostly for our factory to use.
Page
Return User OSD
Save Settings
Load Saved Settings
Load Factory Default
Load All User Default
Burn In Mode
Factory
Burn In Timer Setup hours
Burn In Timer Running hours &
minutes
RS232 Baudrate
OSD Timer
Usage Hour
Software version
All manuals and user guides at all-guides.com

10. Factory OSD Operation

Items
Quit Factory OSD and return user OSD
Save current settings of factory OSD to EEPROM
Load previous saved settings from EEPROM
Load factory default
Restore all settings of user
OSD and PC/HD timing parameters
Burn-In mode On/Off
Set burn-in hours
Running hours of burn-in mode
Set baudrate of RS2329600 or 115200
OSD automatic off time
Record total usage hours of this projector
Software version
Comment