3.Definition
3.1 Failure Criteria:
The product is expected to perform to its full potential without loss of function,
performance, critical parametric changes, and other undesirable anomalies, over the
applied boundaries of this specification. The following product failure are not allowed within
the boundaries defined in this specification:
1.Failure including permanent damage, critical parametic changes (optical
performance defined in Appendix A), and latent defects.
2.Failure requiring operator intervention.
3.Failure violating external laws, regulatory agency standards, and government
directives.
4.Failure resulting in a safety, potential safety, issue.
3.2 EUT: Equipment under Test
3.3 Q: Peak Acceleration Response divided by acceleration input peak
4.Test Order
Atmospherics, Dynamic, and Safety test sets require separate units and can be
processed in parallel. EUT testing shall be performed serially within each set.
Set 1 (3 units)
Dynamics:
Package Drop
Package Vibration Temperature/Humidity,
Shock
Bench Drop
All manuals and user guides at all-guides.com
Set 2 (3 units)
Atmospherics:
Temperature/Humidity, Operating
Non-operating
Altitude, Operating
Aging
Set 3
Safety/EMC:
EFT
ESD
EMI-Radiated
EMI-Conducted
EMI-Susceptibility
14