LMI Technologies, Inc. Trademarks and Restrictions Gocator™ is a registered trademark of LMI Technologies, Inc. Any other company or product names mentioned herein may be trademarks of their respective owners. Information contained within this manual is subject to change.
Introduction 1 Introduction This document provides supplementary information for using Gocator 2075. Reader should refer to Gocator user manual and quick start guide for descriptions and safety precautions of Gocator. Cited sections from the User Manual are shown in italics.
2 Rut Scanning System Setup 2.1 Layout The Gocator 2075 is designed to cover a scan width of up to 4.2m by using 8 sensors mounted in parallel. A Gocator 2075 for rut scanning should typically set the clearance distance (CD) to 800mm and measurement range (MR) to 625mm.
IP address must be unique. To configure a Gocator 2075 for the first time: 1. Setup the sensor’s IP address. a. Follow the steps in the Running a Standalone Sensor System section.
System Operation 3 System Operation The isolated layout should be used. Under this layout, each sensor can be independently controlled by the SDK. The following application notes explain how to operate a multi-sensor system using the SDK. Gocator-2000-2300_Appnote_Multi-Sensor-System_R1.0.zip Explains how to use the SDK to create a multi-sensor system, and multiplex their timing. Gocator-2000-2300_Appnote_Multi-Sensor_Alignment_Calibration_R1.0.zip Explains how to use the SDK to perform alignment calibrate a multi-sensor system.