Download Print this page

MadgeTech PRTC210 Product Information Card

Thermocouple temperature and data logger

Advertisement

Quick Links

Part Number
Internal Channel Temperature Sensor
Internal Channel Temperature Range
Internal Channel Temperature Resolution
Internal Channel Temperature Accuracy
Remote Channel Temperature Sensor
Remote Channel Temperature
Range, Resolution and Accuracy
Pressure Sensor
Pressure Range (Nominal)
Pressure Resolution
Pressure Accuracy
Cold Jct. Compensation
Channels
Memory
Sample Rate
LED Indicator
Required Interface Package
Baud Rate
Typical Battery Life
Operating Environment
Dimensions
Material
Approvals
* Remote Channel
Thermocouple
Range (°C)
J
-210 to +760
K
-260 to +1370
T
-260 to +400
E
-260 to +980
R
-50 to +1760
S
-50 to +1760
B
+60 to +1820
N
-260 to +1300
**PRTC210
Range (PSI)
Accuracy
Resolution (PSI)
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE,
FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY
LEAK OR EXPLODE IF HEATED ABOVE 80°C (176°F).
Specifications subject to change.
See MadgeTech's terms and conditions at www.madgetech.com
MadgeTech, Inc.
6 Warner Road
Phone 603.456.2011
www.madgetech.com
PRTC210
Semiconductor
-20 to +80°C
0.1°C
+0.5°C
Thermocouple Types
J, K, T, E, R, S, B, N
*See Table Below
Semiconductor (strain gauge)
**See Table Below
Automatic
2 Internal & 1 Remote
10,922/channel
2 seconds up to 12 hours
Red
IFC110 or IFC200
57,600
10 years
–20 to +80°C, 0 to 95%RH (non-condensing)
2.2" x 2.5" x 0.9" (55mm x 63mm x 22mm)
Delrin
Resolution
Accuracy
0.1°C
+0.5°C
0.1°C
+0.5°C
0.1°C
+0.5°C
0.1°C
+0.5°C
0.5°C
+2.0°C
0.5°C
+2.0°C
0.5°C
+2.0°C
0.1°C
+0.5°C
0-30
0-100
0-300
0-1000
0-5000
2% FSR, 0.25% @ 25°C typical
0.002
0.005
0.02
0.05
0.05
Warner, NH 03278
l
Fax 603.456.2012
l
info@madgetech.com
l
DOC-1158035-00 REV 11 2012.04.09
Product Information Card
PRTC210
Thermocouple Temperature and Data Logger
PRTC210
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
To view the full MadgeTech product line,
visit our website at
www.madgetech.com.

Advertisement

loading

Summary of Contents for MadgeTech PRTC210

  • Page 1 Red 485 LEAK OR EXPLODE IF HEATED ABOVE 80°C (176°F). Dark Blue Pantone 289 Light Blue 58% of Pantone 289 Specifications subject to change. See MadgeTech’s terms and conditions at www.madgetech.com MadgeTech, Inc. 6 Warner Road Warner, NH 03278 Phone 603.456.2011 Fax 603.456.2012...
  • Page 2 Recalibration Plug the serial cable into the port and verify it is secure. The PRTC210 standard calibration is one point at 25°C for the internal temperature sensor and 0mV for the thermocouple. The pressure calibration depends on the range. Installing the software Insert the Software CD in the CD-ROM Drive.