Cannot Connect to Voyager with the Ethernet Port, But Console Access Works
Cannot Connect to Voyager with the Ethernet Port, But Console Access Works
Cause
Solution Use a crossover Ethernet cable if you are connecting directly to the
Cause
Solution View the port in Voyager or from Lynx and verify that the interface is
Cause
Solution Check host Ethernet port settings. Verify that IP address and netmask
Cause
Solution Verify that the port on the host and the port on the IP700 Series appliance
Cause
Solution Correct duplex setting.
Do Not See Interfaces that Should be Present
Cause
Solution Your card might be defective. Contact the appropriate Nokia customer
IP700 Series Installation Guide
All manuals and user guides at all-guides.com
Using wrong Ethernet cable.
computer. Use a straight-through cable if you are connecting to a hub. For
cabling information, see "Connecting to Ethernet Devices" on page 86.
Port is not configured UP.
configured as active.
Host port configuration is incorrect.
settings are correct for the IP700 Series appliance configuration.
Wrong link speed.
are set for the same speed (10 Mbps or 100 Mbps). An unblinking data
and activity LED on a port is a good indication that the speed is
mismatched.
Duplex setting is wrong.
Local IP700 Series appliance ports do not appear.
support site as listed in the Nokia Contact Information section at the front
of this guide.
NOTE:
The problem might occur at the slot on the motherboard. Try
locating the card in a different slot.