This one may be attached to lock A-Without Key Cylinder B-With Key Cylinder 3rd Party (Mortise & Cylinder) Warning: Install only on a mortise with anti-panic and an auxiliary dead latch (Anti-Pick system) Confidant RFID Kit 2 & Kit 3 PK3649_T 09-21...
Inside Trim Inventory Kit Post may be with Thumbturn without Thumbturn attached to lock 3rd Party (Mortise) Warning: Install only on a mortise with anti-panic and an auxiliary dead latch (Anti-Pick system) Confidant RFID Kit 2 & Kit 3 PK3649_T 09-21...
Post may be attached to lock A-Without Key Cylinder B-With Key Cylinder 3rd Party (Mortise & Cylinder) Warning: Install only on a mortise with anti-panic and an auxiliary dead latch (Anti-Pick system) Confidant RFID Kit 2 & Kit 3 PK3649_T 09-21...
Inside Trim Inventory Kit with Thumbturn without Thumbturn Post may be attached to lock 3rd Party (Mortise) Warning: Install only on a mortise with anti-panic and an auxiliary dead latch (Anti-Pick system) Confidant RFID Kit 2 & Kit 3 PK3649_T 09-21...
1- Check Handing: Adjust for Right Hand (RH) or Left Hand (LH) 2- Insert Spindle 3- Attach and Clamp Spindle Clip to Spindle as shown . Ensure legs are firmly clamped against the spindle Confidant RFID Kit 2 & Kit 3 PK3649_T 09-21...
Install Outside Lever Left Hand WARNING CAUTION IMPORTANT Hold down the outside lever against the outside housing while tightening the lever set screw. Right Hand Confidant RFID Kit 2 & Kit 3 PK3649_T 09-21...
Align Posts with Mortise (Rose Mount Only) WARNING CAUTION IMPORTANT Ensure Mortise lock case includes an anti-pick and anti-panic function Confidant RFID Kit 2 & Kit 3 PK3649_T 09-21...
See Annex A for Exterior Applications Post may be attached to lock WARNING 3mm to 13mm CAUTION IMPORTANT After connecting all cables, make sure all excess cables are pushed inside the hole(s) in the door. Confidant RFID Kit 2 & Kit 3 PK3649_T 09-21...
• A always required • C recommended WARNING Screw M5 (5mm) 3mm to 13mm CAUTION IMPORTANT After connecting all cables, make sure all excess cables are pushed inside the hole(s) in the door. Confidant RFID Kit 2 & Kit 3 PK3649_T 09-21...
See Annex A for Exterior Applications Post may be attached to lock WARNING CAUTION IMPORTANT After connecting all cables, make sure all excess cables are pushed inside the hole(s) in the door. Confidant RFID Kit 2 & Kit 3 PK3649_T 09-21...
* Post may be attached to lock ** Recommended for more security WARNING CAUTION IMPORTANT After connecting all cables, make sure all excess cables are pushed inside the hole(s) in the door. Confidant RFID Kit 2 & Kit 3 PK3649_T 09-21...
F - Check Bolt Projection from Thumbturn & Key B - Check Green & Red Lights Flash C - Rotate Outside Lever to Check Bolt Retraction Program Lock With Jack Cable Confidant RFID Kit 2 & Kit 3 PK3649_T 09-21...
For security reasons, lock must be programmed BEFORE installing the battery door. Every time the bat- tery door is removed pass an emergency card or connect lock to Kaba handheld programming device to reset the tamper alarm. Audit information is not affected. CAUTION IMPORTANT Confidant RFID Kit 2 & Kit 3 PK3649_T 09-21...
0432 EN 179:2008 Emergency exit device Type 376B1452AD dormakaba Canada Inc. 7301 Decarie, Montreal, QC, Canada H4P 2G7 0432-CPR-00026_98 Capacity to trigger: Responds ( = < 70 N without load) Durability of capacity to trigger: Responds ( 200,000 cycles / = < 50 N without load) For declaration of performance, Fire resistance B - Automatic closing;...
Annex A • Install Outside Housing with Gasket and Cylinder Shield (Exterior and Ocean Front Versions) Model with Key Cylinder only Annex B • Remove Battery Holder Unscrew Remove Door Unclip Battery Holder Remove Battery Holder Confidant RFID Kit 2 & Kit 3 PK3649_T 09-21...
Annex C • Install Bluetooth and Messenger module Battery must be disconnected before adding Bluetooth and Messenger module. See annex D for instructions of how to remove the cover from the module. Confidant RFID Kit 2 & Kit 3 PK3649_T 09-21...
Orientation when Messenger Orientation when Messenger hub Position of Bluetooth hub outside the room inside the room antenna board NOTE: Battery must be connected last, after having connected the Bluetooth and Messenger module Confidant RFID Kit 2 & Kit 3 PK3649_T 09-21...
Annex E • DIN Lever Installation Confidant RFID Kit 2 & Kit 3 PK3649_T 09-21...
Page 26