This installation manual does not contain any system design documentation. System design documentation is available from exodraft. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with applicable codes and standards.
1.1 Function The exodraft model RS chimney fan is a chimney top mounted ventilator that is designed to provide large flue gas volume capacities. It is designed and intended for use with residential gas or oil fired central space heating systems, for volume water heating or for combination space heating/volume water heating.
3000270 RS gas and oil 20210818 - international 2. Specifications 2.1 Dimensions and capacities exodraft chimney fan model RS 009 RS 012 RS 014 RS 016 Discharge Horizontal Fan type Axial vane Motor type Totally enclosed, Variable speed, Class H...
Adequate fresh air must be provided for combustion; otherwise, improper operation and inadequate venting of deadly flue gases may result. Support system for the exodraft chimney fan Prior to installation of the chimney fan, it must be assured the chimney can safely carry the weight of the chimney fan.
If the brackets touch the flue wall, it may create some vibration noise. Step 3: Attaching the fan The exodraft chimney fan is now ready for installation on the top of the chimney. Place the fiber mat on the top of the adapter, and place the fan on top of the mat.
3000270 RS gas and oil 20210818 - international 3.3 Single fan on brick chimney Step 1: Prepare fan location The installation procedure is the same whether the flue is round or square. If a clay tile flue liner is installed, it might stick up a few inches. Cut it back so it is flush with or no more than 1/2‘‘...
3000270 RS gas and oil 20210818 - international 3.4 Multiple fans on steel chimney If two or more chimney fans are required to create sufficient draft, installation procedures are the same as for single fan installation on a steel chimney. The only difference is that the fans are sitting next to each other on the top of the chimney.
Please refer to the PDS Installation Manual if this control is used. For more information on alternative safety systems, please contact exodraft a/s. The figure shows the location of the probe for the PDS. Location is important to make sure there is enough pressure or draft available for the switch to work.
RS 016: 1x120 V/60Hz, 3.9 Amps The exodraft chimney fans have a split capacitor motor with infinitely variable speed. The fan speed control supplied is rated 1x120V/60 Hz and 5 Amps. It has an adjustable low voltage set point of min. 65 V +/- 5 V.
3000270 RS gas and oil 20210818 - international 4.3 Wiring diagram for two fans with fan speed control The diagram below shows the wiring of two chimney fans and how they are connected to the fan speed control. PROVEN DRAFT SWITCH 24 VAC MOTOR...
Before any adjustments are made to the system, follow these procedures: 1. Turn the exodraft chimney fan ON and make sure that it is operating. Increase and decrease the speed of the fan by adjusting the fan speed control to make sure it is operating properly.
Screw from each Hinge 6.2 Care and cleaning The exodraft Chimney Fan is designed for prolonged use. The fan should be inspected at least once a year when the chimney is inspected. Fuel residues and other deposits should be removed from the fan blades and the bottom of the motor housing.
• The fan is oversized and running • Reduce the fan speed too fast Mechanical noise can be • Foreign matter may be stuck • Remove matters heard • Motor bearings may be worn out • Replace bearings Service: info@exodraft.dk or at tel: +45 7010 2234...
Page 15
3000270 RS gas and oil 20210818 - international Notes...
Need help?
Do you have a question about the RS 009 and is the answer not in the manual?
Questions and answers