Danfoss PVG 32 Service Manual page 7

Hide thumbs Also See for PVG 32:
Table of Contents

Advertisement

'ffi@
Service
Manual
PVG
32
Proportional
Valve
Group
System
Troubleshooting
Hydraulic (remote)
pilot control
pressure
Cause
Check
Corrective
action
lncorrect signal
voltage
Check
voltage
levels
at solenoid
plug
Proportional operation -
Refer
to
Troubleshooting
Considerations
Udc:
Supply voltage
(1007o)
Us:
Suppfy
si
gnal
voltag
e
(25-50-7
5o/ol
Ground:
Live
or
ground connection
On-Off Operation
Udc:
5upply voltage
if
selected
Us:
Supply
voltage
if
selected
Ground:
Live
or
ground connection
Solenoid valve
faulty
PVHC
Check
coil resistance
Check
data
for
resistance
Insufficient
pilot supply
Check
pilot
pressure
-
10-15 bar
[145-218
psi]/PVHC 25
bar [360
psil
Replace
Main spool
position
feedback
transducer signal
incorrect
Test
oil for
contamination
and or water
content
lf
oilcontamination
is
too
high, flush hydraulic
system
or replace oil if
necessary.
lf problem
persists
change
PVE
lncorrect
PVE
connections
Check
that
the proportional
remote electrical
controller
has
not
been
connected
to
an ON-OFF
PVEO
solenoid
Connect wires correctly
Cause.,,
Check
Corrective action
Insufficient
pilot
pressure
Check
pilot oil
pressure 5-15
bar
t72-22O
psil delta between
A
and
B
port on
remote
PVG32:5-15
Bar 172-217 PSll
Insufficient
pilot oil supply
Check
pilot
oilflow
rate
is
adequate
Pilotflowshould
be
1.0
L/min
[0.264 GPM]
persection
Check
pilot
lines
for blockage
Remove blockage
Air in
pilot line
Check
for
trapped
air
in
pilot
lines
Bleed air
from pilot
lines
at
PVH
Pilot lines incorrectly
sized
Check pressure
drop
Check
and reduce
length
or
pilot
lines
Increase
diameter of
pilot
lines
Use
steel tube
for
long
pilot
line runs
Hydraulic remote
pilot operator
faulty
Check
operation
of hydraulic remote
pilot controller
Repair
or replace
Check
supply
pressure
to
hydraulic remote
controller- minimum
25
bar
[360
psi]
Repair
or replace
Check
and inspect movement of
pressure
control
valve
in
hydraulic
controller
Repair
per manufacturers procedure,
or
replace
Check
operaticin of remote hydraulic
controller
Clean
and/or
repair
as
necessary
1
I O39l
67
.
Rev
BA
. May
201
4

Advertisement