Download Print this page

Description Of Terminals - F&F AS-225D Instructions Manual

12-channel cascade controller

Advertisement

Description of terminals

Power
supply
+
Control
DOWN
input
Power supply of the controller
Warning! Maintain proper power
supply polarity as indicated on the
enclosure.
Warning! If the simultaneous load of
the controller exceeds 12÷16 A, con-
nect two independent power wires "–"
to the first and second terminal of the
controller and lead them to the power
supply unit.
A short press on the DOWN button
starts the cascade moving from the
bottom to the top. The circuits will
be switched on starting from OUT 1,
OUT 2, OUT 3 and so on until the last
controlled output is reached. Each of
the outputs will be switched on for the
time TIME (set by the knob on the con-
troller). The delay between switching
on subsequent outputs is set on the
controller with the DELAY knob.
Warning! If the DOWN button remains
pressed the lights remain on for the
duration of the pressing. The shutdown
sequence of each output will begin
when the DOWN button is released.
- 7 -