Brightness level in the off state. Setting range
from 0 to 25 %. This parameter enables the "night
light" feature - setting a non-zero brightness level
will cause the lights to glow gently all the time,
and only when the cascade is triggered will they
OFF
light up to full brightness.
LEVEL
Warning! The "night light" feature should be
combined with an external brightness sensor
connected to the OFF input. Such will cause the
controller and the "night light" feature to work
only at the actual low brightness level.
LED signalling
U
Controller power indication
OUT
Output circuit power indication
Signalling that the acceptable temperature inside
the controller is exceeded.
Warning! The AS-225D controller is equipped
with thermal protection to prevent excessive
OVER-
overloading of the output circuits.
TEMP
If the temperature limit is exceeded, the pro-
tection starts to work and limits the maximum
brightness level first. It is only when the tempera-
ture continues to rise that the controller outputs
are completely disconnected.