Control
OFF
input
OUT1
Output
÷
circuits
OUT12
Triggering of the OFF input (for example
by an external brightness sensor)
switches off all controlled output
circuits. The lights in this mode are
completely off, regardless of the OFF
LEVEL parameter setting. Operation of
the DOWN and UP buttons in this mode
is also disabled.
Outputs for connecting light sources.
Pay attention to the order of connec-
tion and the power of the light source.
Connect the "–" wire of the lights to
the OUT terminals, and connect the "+"
wire directly to "the "+" of the power
supply (according to the installation
diagram above).
The maximum current of a single lamp
shall not exceed 4 A, while the total
current of all lamps switched on at the
same time shall not exceed 24 A.
Warning! Provide a power supply unit
of sufficient capacity to guarantee
proper powering of both the controller
and all operating sources. Overloading
the power supply usually results in a
power cut, which will interrupt the
controller operation.
- 9 -