Error
The platform and
bucket mount do not
move properly.
Incorrect solvent saturation
readings
7.4.2
Resolving errors
If errors persist after following these steps, contact
provider
for additional guidance.
Error
The bucket is already down
The bucket is already raised
The device position is
unknown
The device is already
moving
The call to DBus failed
The reply to the DBus was
invalid
Moving the motor failed
The device is not currently
running
36
Cause
•
Debris or obstructions in the
wash bucket
•
Firmware issue
•
Bubbles on solvent monitor
•
Mismatch between selected
solvent and solvent in wash
bucket
Cause
The Form Wash L attempted
to lower the basket mount and
platform mount when they were
already at their bottom position.
The Form Wash L attempted
to raise the basket mount and
platform mount when they were
already at their top position.
The Form Wash L attempted
to raise the basket mount and
platform mount when they were
in an unknown position.
The Form Wash L attempted to
raise or lower the basket mount
and platform mount while they
were still in motion.
Firmware error
Firmware error
The Form Wash L
encountered an error during a
motor movement.
The Form Wash L attempted to
cancel an ongoing cycle with no
cycle in progress.
Solution
•
Check for loose cured material
or debris in the bottom of the
wash bucket.
•
Update the firmware
•
Check the solvent monitor for
bubbles
•
Check that the selected solvent
matches the solvent in the Form
Wash L
Formlabs Support
or a
Solution
Disconnect and reconnect the power.
Disconnect and reconnect the power.
Disconnect and reconnect the power.
Disconnect and reconnect the power.
Disconnect and reconnect the power.
•
Disconnect and reconnect
the power.
•
Check for debris or obstructions
that would prevent the platform
mount from moving.
•
Disconnect and reconnect
the power.
•
Check for debris or obstructions
that would prevent the platform
mount from moving.
Disconnect and reconnect the power.
certified service
Need help?
Do you have a question about the Form Wash L and is the answer not in the manual?
Questions and answers