ERGA04~08EA + EHVH04+08SU18+23EA
Daikin Altherma 3 R F
4P629090-1A – 2021.11
2
Malfunctioning
Room
Main zone
Additional zone
Space heating/cooling
Setpoint screen
Control the leaving water temperature for the main zone via setpoint screen [2]
Main zone.
See
"10.3.5 Setpoint
screen" [
Schedule
Indicate if the temperature of the leaving water is defined according to a schedule
or not.
Influence of the LWT setpoint mode [2.4] is as follows:
In Fixed LWT setpoint mode, the scheduled actions consist of desired leaving
water temperatures, either preset or custom.
In Weather dependent LWT setpoint mode, the scheduled actions consist of
desired shift actions, either preset or custom.
#
Code
[2.1]
N/A
Heating schedule
Define a heating temperature schedule for the main zone via [2.2] Heating
schedule.
See
"10.4.3 Schedule screen:
Cooling schedule
Define a cooling temperature schedule for the main zone via [2.3] Cooling
schedule.
See
"10.4.3 Schedule screen:
[2] Main zone
Setpoint screen
[2.1] Schedule
[2.2] Heating schedule
[2.3] Cooling schedule
[2.4] Setpoint mode
[2.5] Heating WD curve
[2.6] Cooling WD curve
[2.7] Emitter type
[2.8] Setpoint range
[2.9] Control
[2.A] Thermostat type
[2.B] Delta T
[2.C] Modulation
[2.D] Shut off valve
[2.E] WD curve type
4
 149].
Description
Schedule:
0: No
1: Yes
4
Example" [
 154].
4
Example" [
 154].
10
Configuration
|
Installer reference guide
171