Daikin Altherma 3 R F Installer's Reference Manual page 123

Hide thumbs Also See for Daikin Altherma 3 R F:
Table of Contents

Advertisement

ERGA04~08EA + EHVH04+08SU18+23EA
Daikin Altherma 3 R F
4P629090-1A – 2021.11
A
B
A
B
X1M
a Interconnection cable (=main power supply)
In case of preferential kWh rate power supply
Interconnection cable
(= main power supply)
Normal kWh rate
power supply
Preferential kWh rate
power supply contact
[9.8] Benefit kWh power supply
Connect X11Y to X11YB.
1 2 3
a
1 2 3
X2M
X11YB
X11YA
X11Y
X1A
Wires: (3+GND)×1.5 mm²
Wires: 1N
Maximum running current: 6.3 A
Wires: 2×(0.75~1.25 mm²)
Maximum length: 50 m.
Preferential kWh rate power supply contact:
16 V DC detection (voltage supplied by PCB). The
voltage-free contact shall ensure the minimum
applicable load of 15 V DC, 10 mA.
9
Electrical installation
|
a
Installer reference guide
123

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents