16.7 Table 3 – Minimum bottom opening area for natural ventilation:
indoor unit
m
m
c
max
1.9
0.1
1.9
0.3
1.9
0.5
1.9
0.7
1.9
0.9
1.9
1.1
1.9
1.3
1.9
1.5
1.9
1.7
ERGA04~08EA + EHBH/X04+08EF
Daikin Altherma 3 R W
4P629085-1B – 2021.11
INFORMATION
H = Height measured from the bottom of the casing to the floor.
For intermediate H values (i.e. when H is between two H values from the table),
consider the value that corresponds to the lower H value from the table. If
H=1450 mm, consider the value that corresponds to "H=1400 mm".
Systems with a total refrigerant charge (m
<27 m) are NOT subjected to any requirements to the installation room.
Charges >1.9 kg are NOT allowed in the unit.
dm=m
–m
(kg)
c
max
H=1150 mm
H=1200 mm
1.80
538
1.60
479
1.40
419
1.20
359
1.00
299
0.80
240
0.60
180
0.40
120
0.20
63
INFORMATION
H = Height measured from the bottom of the casing to the floor.
For intermediate H values (i.e. when H is between two H values from the table),
consider the value that corresponds to the lower H value from the table. If
H=1450 mm, consider the floor area that corresponds to "H=1400 mm".
For intermediate dm values (i.e. when dm is between two dm values from the
table), consider the value that corresponds to the higher dm value from the table.
If dm=1.55 kg, consider the value that corresponds to "dm=1.6 kg".
Minimum bottom opening area (cm
H=1300 mm
H=1400 mm
515
495
477
458
440
424
401
385
371
344
330
318
287
275
265
229
220
212
172
165
159
115
110
106
58
55
53
16
Technical data
|
) <1.84  kg (i.e. if the piping length is
c
2
)
H=1500 mm
H=1600 mm
H=1700 mm
461
446
433
410
397
385
359
347
337
308
298
289
256
248
241
205
199
193
154
149
145
103
100
97
52
50
49
Installer reference guide
H=1800 mm
421
374
327
281
234
187
141
94
47
279