ERGA04~08EA + EHBH/X04+08EF
Daikin Altherma 3 R W
4P629085-1B – 2021.11
Item
Remote outdoor sensor
Remote indoor sensor
Human Comfort Interface
(in case of DHW tank)
3‑way valve
(in case of DHW tank)
Domestic hot water tank
thermistor
9
Electrical installation
|
Description
See:
▪
Installation manual of the remote outdoor
sensor
▪
Addendum book for optional equipment
Wires: 2×0.75 mm²
[9.B.1]=1 (External sensor = Outdoor)
[9.B.2] Ext. amb. sensor offset
[9.B.3] Averaging time
See:
▪
Installation manual of the remote indoor
sensor
▪
Addendum book for optional equipment
Wires: 2×0.75 mm²
[9.B.1]=2 (External sensor = Room)
[1.7] Room sensor offset
See:
▪
Installation and operation manual of the
Human Comfort Interface
▪
Addendum book for optional equipment
Wires: 2×(0.75~1.25 mm²)
Maximum length: 500 m
[2.9] Control
[1.6] Room sensor offset
See:
▪
Installation manual of the 3-way valve
▪
Addendum book for optional equipment
Wires: 3×0.75 mm²
Maximum running current: 100 mA
[9.2] Domestic hot water
See:
▪
Installation manual of the domestic hot
water tank
▪
Addendum book for optional equipment
Wires: 2
The thermistor and connection wire (12 m)
are delivered with the domestic hot water
tank.
[9.2] Domestic hot water
Installer reference guide
117