ERGA04~08EA + EHBH/X04+08EF
Daikin Altherma 3 R W
4P629085-1B – 2021.11
Setpoint mode
#
Code
[5.B]
N/A
WD curve
When weather dependent operation is active the desired tank temperature is
determined automatically depending on the averaged outdoor temperature: low
outdoor temperatures will result in higher desired tank temperatures as the cold
water tap is colder and vice versa.
In case of Schedule
preparation, the storage comfort temperature is weather dependent (according to
the weather dependent curve), the storage economic and reheat temperature are
NOT weather dependent.
In case of Reheat
temperature is weather dependent (according to the weather dependent curve).
During weather dependent operation, the end-user cannot adjust the desired tank
temperature on the user interface. Also see
4
curve" [
158].
Setpoint mode:
▪
Fixed
▪
Weather dependent
only or Schedule
only domestic hot water preparation, the desired tank
10
Configuration
|
Description
+
reheat domestic hot water
"10.5 Weather-dependent
Installer reference guide
197