Daikin Altherma 3 R W Installer's Reference Manual page 21

Hide thumbs Also See for Altherma 3 R W:
Table of Contents

Advertisement

ERGA04~08EA + EHBH/X04+08EF
Daikin Altherma 3 R W
4P629085-1B – 2021.11
"15 Disposal" [
Disposal (see
DANGER: RISK OF EXPLOSION
Pump down – Refrigerant leakage. If you want to pump down the system, and there
is a leak in the refrigerant circuit:
Do NOT use the unit's automatic pump down function, with which you can collect
all refrigerant from the system into the outdoor unit. Possible consequence: Self-
combustion and explosion of the compressor because of air going into the
operating compressor.
Use a separate recovery system so that the unit's compressor does NOT have to
operate.
3
Specific installer safety instructions
|
4
 265])
Installer reference guide
21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents