Instruction book
Drawing Reference
* Refer to your Atlas Copco Customer Centre for detailed info
Position of components
Air flow
Air drawn through filter (AF) is compressed in compressor element (E). Compressed air and oil
are discharged through check valve (CV) to air receiver/oil separator (AR) where oil is separated
from the compressed air. The air is blown through minimum pressure valve (Vp) to air cooler
(Ca).
On Pack compressors, the cooled air is discharged through the condensate trap and the outlet
towards the air net.
Check valve (CV) prevents blow-back of compressed air.
Minimum pressure valve (Vp) prevents the receiver pressure from dropping below a minimum
pressure. The valve has a built-in check valve.
APF221384
Description
(3)
Condensate drain of the dryer
(4)
Condensate drain of the compressor
(5)
Energy recovery circuit (optional)
(6)
Air inlet
(7)
Air outlet