INSTALLATION

5.10 Positioning the draught terminals

The draught terminals must:
• be positioned on the outer perimeter walls of
the building or on the roof;
• comply with the minimum distances Figure
5.16 and any national or local regulations.
Position of the terminal
A Under the window or other opening
B Next to a window or door
B Next to an air vent or ventilation
opening
C Side of a balcony
D Under the gutter or discharge pipes
E
Under the eaves
F
Under balconies
G Under the garage roof
H From vertical discharge pipes
I
From inner corners
J
From external corners
K From the ground or other floor sur-
faces
L
From a front facing surface without
openings
M From a front facing opening
N From an opening in the garage
O Between two vertical terminals in
the same wall
P Between two horizontal terminals
in the same wall
Q Above the pitch of a roof with a
slope less than or equal to 30° *
Q Above the pitch of a roof with a
slope greater than 30° *
R Above a flat roof *
S
From a wall *
S
From two walls at an angle *
* Roof-mounted terminal
mm
600
400
600
1000
300
300
300
NO
300
300
300
2200
2000
3000
NO
1500
1000
350
600
300
600
1000