Page 1
All manuals and user guides at all-guides.com TEMPERATURE AND PRESSURE GAUGE English Installation and operating guide Temperature And Pressure Gauge...
Page 2
All manuals and user guides at all-guides.com Instruction Manual TAP / Te Contents Introduction ....General information ..Important safety notice .. Technical Data ....Parts description .... Transport, packaging and Setup, operation .... Maintenance ....Guarantee ...... Replacement parts and a...
All manuals and user guides at all-guides.com Instruction Manual TAP / Temperature And Pressure Gauge English Contents Introduction ..................4 General information ................ 6 Important safety notice ..............7 Technical Data ................. 8 Parts description ................9 Transport, packaging and storage ..........13 Setup, operation ................
- Uses common AAA batteries. harmful interference to ra However, there is no gua - TAP is available in a suitable case either as single or double set. particular installation. If rence to radio or televisi turning the equipment o...
Page 5
- Create report and send by e-mail to your office. All manuals and user guides at all-guides.com - Uses common AAA batteries. - TAP is available in a suitable case either as single or double set. rature And Pressure Gauge Instruction Manual TAP / Temperature And Pressure Gauge...
The TAP has been developed for long term use. REFCO takes energy m The TAP must not be u Technical Data The TAP has been developed for long term use. REFCO takes energy saving and saving and environmental impact into consideration when procuring psi / 6000 kPa.
The TAP must not be used for anything other than the below-stated purposes. Illustration Explanation The TAP should not be exposed to moisture or used in damp or wet environments. Warning: Seriuos physical injury can occur Damage to the equipment may occur Remove refrigerants from the TAP and the hoses after use.
All manuals and user guides at all-guides.com English Instruction Manual TAP / Temperature And Pressure Gauge Instruction Manual TAP / Te Technical Data The TAP can be used with Temperature clamp, TAP-CLAMP R11, R113, R114, R12, R R23, R290, R32 R401A(L...
And Pressure Gauge Instruction Manual TAP / Temperature And Pressure Gauge English The TAP can be used with the following refrigerants: R11, R113, R114, R12, R123, R124, R13, R134a, R13B1, R22, R227, R23, R290, R32 R401A(Liq), R401A(Vap), R401B(Liq), R401B(Vap),...
Page 10
All manuals and user guides at all-guides.com English Instruction Manual TAP / Temperature And Pressure Gauge Instruction Manual TAP / Te English Instruction Manual TAP / Temperature And Pressure Gauge Pressure Gauge ON / OFF Pressure Gauge UNIT Slider switch...
Page 11
By pressing [ON/OFF] + [UNIT] button same time < 1 sec. the following mode is activated: UNIT Battery case cover - Set number of TAP-CLAMP. Scroll from T1 to T6 by 4 x 1.5 V AAA pressing [UNIT] button < 1 sec. (once set, setting remains) By pressing [ON/OFF] + [UNIT] button same time >...
Page 12
All manuals and user guides at all-guides.com English Instruction Manual TAP / Temperature And Pressure Gauge Instruction Manual TAP / Te Buttons and functions on TAP Pressure Gauge Display ON / OFF Scroll UP Scroll DOWN MENU ON by short pressing < 1 sec. OFF by pressing ≥ 1 sec.
Transport LED light off. The TAP is delivered from the factory in a plastic box, with or without o wirless connection to different accessories as ordered. Inspect the TAP for any potential mart device. transportation damage. Any obvious damage should be reported to To use TAP without smart the vendor immediately.
- Storage temperature: -20 °C to +60 °C - Humidity: 0 to 90% relative humidity (no condensation) Set-up TAP Insert 4 x 1 ment on th Setup and operation The TAP must not be used for anything other tha Ensure the TAP CLAMP polarities. Purpo...
Page 15
The TAP should not be exposed to moisture or u condensation) Set-up TAP Insert 4 x 1.5 V (AAA) batteries in the battery compart- ment on the back side of the TAP. Remove refrigerants from the TAP and the hose st not be used for anything other than the below-stated purposes.
Page 16
All manuals and user guides at all-guides.com English Instruction Manual TAP / Temperature And Pressure Gauge Instruction Manual TAP / Te Set - Press [MENU] button ≥ 1 sec. to activate selection Pairing - Ensure favorites mode. than 5 m - Press [DOWN] button< 1 sec. to scroll down to the - Ensure T refrigerant menu.
Page 17
If no device can be found, " No Signal" appears on ec. to activate selection display before return to menu. sec. to scroll down to the - If device be found, display shows a list of found TAP CLAMP ID(s). c. unit field will flash. - Select desired TAP CLAMP ID by pressing [UP] or on <...
Page 18
All manuals and user guides at all-guides.com English Instruction Manual TAP / Temperature And Pressure Gauge Instruction Manual TAP / Te Maintenance Update Updating refrigerants. See in chapter maintenance. • A visual inspection o Version Current version of refrigerant chart is shown.
The TAP pressure sensor can be reset in order to avoid incorrect mea- surement values. The TAP should not be exposed to moisture or used in damp or we P-Zero To obtain a correct measurement value on the display, the Remove refrigerants from the TAP and the hoses after use.
Page 20
Calibration of temperature clamp 3. While holding [UNI or by using room temperature as reference. The TAP should not be exposed to moisture or used in damp or w "CALL" Risk of short circuit. If the electronic components come into contact with Calibration of temperature clamp water, short circuits are possible.
Page 21
5. Press [DOWN / SET] button until the display shows a reading The TAP should not be exposed to moisture or used in damp or we perature clamp below max. which is presenting the unload pressure. (i.e. 0.0 psi)
English Instruction Manual TAP / Temperature And Pressure Gauge Instruction Manual TAP / Te Guarantee Your new TAP has been developed in accordance with the latest oc- cupational health and ergonomic requirements and reflects the latest state-of-the-art technology. REFCO Manufacturing Ltd has been certi- fied in accordance with DIN EN ISO 9001: 2008. Regular quality con- trol checks as well as an accurate manufacturing process guarantee...
Page 23
All manuals and user guides at all-guides.com rature And Pressure Gauge Instruction Manual TAP / Temperature And Pressure Gauge English dance with the latest oc- nts and reflects the latest turing Ltd has been certi- 008. Regular quality con- turing process guarantee the REFCO guarantee, in nditions of Sale and Deli- ages arising from obvious e guarantee.
Page 24
All manuals and user guides at all-guides.com English Instruction Manual TAP / Temperature And Pressure Gauge REFCO Manufacturing Ltd. Industriestrasse 11 6285 Hitzkirch - Switzerland Telefon +41 41 919 72 82 Telefax +41 41 919 72 83 info@refco.ch www.refco.ch...
Need help?
Do you have a question about the TAP and is the answer not in the manual?
Questions and answers