Fixture Information; Custom Settings And Factory Defaults - GLP Fusion Stick FS16Z User Manual

Table of Contents

Advertisement

German Light Products®
- Auto: The display will automatically switch off after a few seconds if the fixture is
receiving a valid control signal and has not detected an error. If the fixture is not
receiving a valid control signal the display will flash. If the fixture has detected an
error, the display will remain constantly on and show the error.
- On: The display stays on constantly. This setting can be useful when you are
configuring or servicing the fixture.
- Off: The display will automatically switch off after a few seconds even if the fixture is
not receiving a valid control signal or if it has detected an error.

Fixture information

The Information menu in the control panel gives access to items of information from
the fixture's sensors and memory. You can check temperature sensor readouts, see
total operating hours counters and power cycle count, and see DMX signal quality
data, for example.

Custom settings and factory defaults

You can customize fixture settings (DMX mode, Pixel orientation, etc.) via DMX or using
the fixture's control panel. Custom settings are stored after a power off/on cycle and
after a reset.
Two options are available in the fixture's control panel for deleting multiple custom
settings and restoring defaults:
● Load Setting Defaults reloads all the fixture's factory default settings except DMX
address, DMX mode and Control protocol. This option returns the fixture to baseline
settings (default Fan mode, Output limitation, Pixel orientation, Dimmer curve, etc.)
without affecting its basic configuration in an installation.
● Load Factory Backup reloads all the fixture's factory default settings including DMX
address, DMX mode and Control Protocol. This option reinitializes the fixture
completely and returns to its state when it left the factory.
Fusion Stick FS16Z User Manual Rev. A
Features
35

Advertisement

Table of Contents
loading

Table of Contents