7 D-Frame Sizes Disassembly and Assembly
Instructions
7
Figure 7.1: Control Card Access
380–480/500V: Yellow tape on the main SMPS transformer in the upper right corner.
525–690V: White tape on the main SMPS transformer in the upper right corner.
1
2
3
4
5
6
7

7.2.2 Control Assembly Support Bracket

1.
2.
3.
Reinstall in reverse order of this procedure. Tighten the mounting screws to 4 Nm (35 in-lbs).
7-2
Local control panel (LCP) (Step 2)
LCPcradle (Step 3)
C-option (if installed)
Mounting screws (Step 5)
Control assembly support bracket
Attaching hardware
Power card mounting plate
Remove the control card mounting plate in accordance with procedure.
Remove the 6 mounting nuts (10 mm), see Figure 7-1.
Remove the control assembly support bracket.
MG.90.L1.22 - VLT
High Power Service Manual for VLT
8
Power card PCA3
9
MK102 ring lug connection
10
DC bus fuse
11
Control card mounting plate
12
Control card terminal block
13
Control card (under LCP)
®
is a registered Danfoss trademark
®