14
While holding the front-center-rear housing assembly
together, turn the assembly over to access the bolt holes on
the rear housing (9).
15
Install the housing bolts (16).
NOTE: Models P1-P4 require four housing bolts; Models P5-P9 require eight
housing bolts. (See photos below.)
16
Attach the housings together by tightening the bolts.
NOTE: Tighten the bolts using a star pattern torque sequence to ensure even
compression on the surfaces of the housing O-rings. Refer to Appendix 1 for
the torque specifications of the fasteners.
Models P1-P4

Installation of Inner Magnet:

17
Insert the inner magnet key (14) into the
keyway of the drive shaft (2).
NOTE: The material of the inner magnet key matches
the material of the gears.
18
Align the keyway of the inner magnet (18)
with the key (14) on the drive shaft (2); then
slide the inner magnet onto the drive shaft.
NOTE: The inner magnet should touch the step on the drive shaft.