Motor Hook-Up; Motor Shaft Direction - Liquiflo POLY-GUARD Series Installation, Operation & Maintenance Manual

Fluoropolymer-lined, magnetic-drive, close-coupled gear pumps
Table of Contents

Advertisement

Liquiflo Installation, Operation & Maintenance Manual
3.8

Motor Hook-Up

Please refer to the motor manufacturer's instructions.
3.9

Motor Shaft Direction

The motor shaft is magnetically coupled to the drive shaft of the pump. Both shafts will turn in the same direction.
Because the gear pump is bi-directional, the pump shaft can turn in either direction to produce flow in either direction.
The direction of rotation of the motor shaft (same as that of the pump drive shaft) will determine which side of the pump
is the inlet (suction side) and which side is the outlet (discharge side). For the Poly-Guard Series pumps, the flow direction
will be as shown below:
Top View of Poly-Guard Series Gear Pump (with Transparent Pedestal) Close-Coupled to Motor
INLET
Flow
Counterclockwise (CCW) Rotation of Motor Shaft:
Fluid will enter the pump at the left side (inlet) and be
discharged at the right side (outlet).
Motor
CCW
Outer
Magnet
Flow
Poly-Guard
Models P1 thru P9, Close-Coupled
Motor Shaft
Pedestal
OUTLET
Flow
Clockwise (CW) Rotation of Motor Shaft:
Fluid will enter the pump at the right side (inlet) and be
discharged at the left side (outlet).
10
®
Series MAG-DRIVE Gear Pumps
Motor
CW
Outer
Magnet
Flow
INLET