5.4
PUMP ASSEMBLY
Follow the procedure below and refer to the Exploded View Drawing on page 27.
5.4.1
Pump Cartridge Assembly
A Pump Cartridge is a complete mag-drive pump less the outer magnet and pedestal. A cartridge replacement is a
convenient way to quickly replace a pump that requires maintenance. Pump cartridges are available from the factory and
are designated by placing a
Pump Cartridge
Parts
Assembly of Gear-Shafts:
NOTE:
Steps 1
and
2
are not applicable if the gear-shaft components were
supplied as part of a Liquiflo Repair Kit. (See chart on following page for repair kit
components and Appendix 2 for additional parts information.)
1
Assemble the drive gear (4) to the drive shaft (2) using one gear
key (13) and one gear retaining ring (5) for Models P1-P4 or
two gear retaining rings (5) for Models P5-P9.
2
Assemble the idler gear (3) to the idler shaft (1) using one gear
key (13) and two gear retaining rings (5).
Caution!
Do not reuse Retaining Rings.
NOTE: The Poly-Guard Series pumps use elastomer
O-rings for the retaining rings and plastic keys which
match the material of the gears.
Idler Gear-Shaft Assembly
Drive Gear-Shaft Assembly
C
in front of the pump model code. Example
(If required; see Note below.)
Poly-Guard
Models P1 thru P9, Close-Coupled
Cartridge
Model Number: CP4UPPEE110BVU.
16
®
Series MAG-DRIVE Gear Pumps
Pump
Cartridge
Retaining
Ring
Key