Replacing Center Plate Inner Seals And Needle Bearings - Liquiflo FTS400 Series Safety, Installation, Operation And Maintenance Instructions

Table of Contents

Advertisement

Liquiflo FTS Transfer Pump User Manual
Series No. FTS400

Replacing center plate inner seals and needle bearings

1. Using a 3 mm hex key, remove the six M4 x 20 mm socket head cap screws from the face plate, Figure 1.
2. Lift the face plate off the center plate, Figure 2. Use pry points if necessary.
3. Remove the center plate inner shaft seals using a seal removal tool, hooking it under the lip of each seal and gently
prying upward, Figure 3.
Figure 1
Seals
Figure 3
Lubricate the inner lips of the shaft seals with Mobilgrease XHP
Continued on next page
Six M4x20 screws
4
Maintenance and service
Figure 2
29