Information On Refrigerant - Bosch Compress 7001i AW User Manual

Air water heat pump with indoor unit
Hide thumbs Also See for Compress 7001i AW:
Table of Contents

Advertisement

Maintenance
The module does not have to have Internet access. It can also be used in
a local network. In this case, the heating system cannot be accessed
through the Internet, and the IP module software is not automatically
updated.
• App Bosch HomeCom Easy
When starting the app for the first time, you will be asked to enter the
login name and password set at the factory. These login details are
printed on the data plate of the IP module.
• SmartGrid
With SmartGrid, the indoor unit can communicate with the energy
exchange and modify the operation of the heat pump so that it is at the
maximum output when the price for the power is the most affordable.
For details of the SmartGrid, refer to the product website.
The login data are lost when the IP module is exchanged.
Each IP module has its own login data.
▶ After commissioning, enter the login data in the corresponding field
of the user instructions.
▶ After exchanging, replace with the data for the new IP module.
Unit designation
Refrigerant type
Compress 7400i AW
R410A
5
Compress 7400i AW
R410A
7
Compress 7001i AW
R410A
5
Compress 7001i AW
R410A
7
Compress 7001i AW
R410A
9
Compress 7001i AW
R410A
13
Compress 7001i AW
R410A
17
Table 32 Information on refrigerant
22
Global warming
CO
equivalent of
2
potential (GWP)
the original fill
volume
[kgCO
eq]
[t]
2
2088
3,654
2088
4,907
2088
3,550
2088
3,654
2088
4,907
2088
6,890
2088
8,352
Alternately, the password can be changed at the control device.
Login data for the IP module
Manuf.
no.:_________________________________________________________________
Login name:_______________________________________________________
Password:_______________________________________________________________
Mac:_____________________________________________________________________
4.4

Information on refrigerant

This device contains fluorinated greenhouse gases as a refrigerant.
The unit is hermetically sealed. The following information on the
refrigerant complies with the requirements of EU Regulation No. 517/
2014 on fluorinated greenhouse gases.
Notice for the user: If your installer adds refrigerant, he enters the added
fill volume and the total amount of the refrigerant in the following table.
Original fill volume
[kg]
1,750
2,350
1,700
1,750
2,350
3,300
4,000
Compress 7001i/7400i AW AWE – 6721835320 (2021/09)
Added
Total amount on
fill volume
commissioning
[kg]
[kg]

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Compress 7401i awCompress 7001i aweCompress 7401i awe