4.2.4

Cleaning of the condensation catch pan

If the control unit displays the alarm that the heat pump needs to be
cleaned, remove the dirt particles and leaves that impair the de-icing
function from the condensation catch pan.
Fig. 8
The heat pump condensation catch pan
[1]
Drain pan
4.3

Connection option for the IP module

The IP module is installed as standard in a number of products and can
be retrofitted to others as an accessory.
To take advantage of all the functions, an Internet connection and router
with a free RJ45 output are necessary. This can lead to additional costs.
The Bosch HomeCom Easy app is required to control the system using
a mobile phone. Functionality is not available in all national markets. For
further information please contact Technical Support.
The IP module can be used to control and monitor the system via a mobile
device. It is used as an interface between the heating system and a
network (LAN) and also enables the SmartGrid function.
The IP module is installed as standard in a number of products and can
be retrofitted to others as an accessory.
Compress 7001i/7400i AW AWE – 6721835320 (2021/09)
WARNING
The evaporator's aluminium fins are thin and sensitive.
The fins have sharp edges. Risk of cuts in the event of careless handling.
▶ Wear protective gloves on your hands to protect against cuts.
▶ Proceed with caution in order not to damage the fins.
To take advantage of all the functions, an Internet connection and router
with a free RJ45 output are necessary. This can lead to additional costs.
The Bosch HomeCom Easy app is required to control the system using
a mobile phone.
The IP module can be used to control and monitor the system via a mobile
device. It is used as an interface between the heating system and a
network (LAN) and also enables the SmartGrid function.
Commissioning
When commissioning, refer to the router documents.
The router must be configured as follows:
• DHCP active
• Ports 5222 and 5223 must not be blocked from outgoing traffic.
• Free IP address available
• Address filtering adapted to the module (MAC filter).
The following options exist for commissioning the IP module:
• Internet
The IP module automatically obtains an IP address from the router. The
name and address of the target server are stored in the factory settings
of the module. Once an Internet connection is established, the IP module
automatically logs on to the Bosch server.
• LAN
Maintenance