Bosch Compress 3000 AW Operating Instructions Manual

Bosch Compress 3000 AW Operating Instructions Manual

Air-water split heat pump

Advertisement

6 720 814 470-00.2I
Air-Water Split Heat Pump
Compress 3000 AW
230V 1N~ / 400V 3N~
VOGEL
NOOT
&
CLIMATE CONTROL SYSTEMS
Operating instructions
ARUN-TWIN.

Advertisement

Table of Contents
loading

Summary of Contents for Bosch Compress 3000 AW

  • Page 1 6 720 814 470-00.2I Air-Water Split Heat Pump Compress 3000 AW 230V 1N~ / 400V 3N~ VOGEL NOOT & CLIMATE CONTROL SYSTEMS Operating instructions ARUN-TWIN.
  • Page 2: Table Of Contents

    Technical terms ......... . 13 6 720 818 009 (2015/07) Compress 3000 AW VOGEL NOOT &...
  • Page 3: General Safety Instructions

    ▶ Do not use or store corrosive substances (solvents, adhesives, chlorinated cleaning agents, etc.) within the vicinity of the appliance. Compress 3000 AW 6 720 818 009 (2015/07) VOGEL NOOT &...
  • Page 4: Overview Of System

    6 720 814 470-03.1l Fig. 1 Heat pump for outdoor unit, indoor unit AWMS/AWMSS with integrated DHW cylinder and electric booster heater 6 720 818 009 (2015/07) Compress 3000 AW VOGEL NOOT & CLIMATE CONTROL SYSTEMS...
  • Page 5 The changeover between heating and DHW is then effected 6 720 814 470-05.1l Fig. 3 Heat pump for outdoor unit, indoor unit AWB without electric booster heater, external DHW cylinder and external auxiliary heater Compress 3000 AW 6 720 818 009 (2015/07) VOGEL NOOT &...
  • Page 6: Overview Of The Most Frequently Used Functions

    ▶ Press to activate the input field for selecting the heating circuit in the standard display (only systems with at least two heating circuits). Table 2 Control elements 6 720 818 009 (2015/07) Compress 3000 AW VOGEL NOOT & CLIMATE CONTROL SYSTEMS...
  • Page 7: Changing The Room Temperature

    ▶ Press and hold down the DHW key and the selector for a few seconds to activate or deactivate the key block. When the key lock is enabled, the key symbol appears in the display ( Fig. 4 [5], page 6). Table 4 More settings Compress 3000 AW 6 720 818 009 (2015/07) VOGEL NOOT &...
  • Page 8: Setting The Operating Mode

    ▶ Turn and press the selector to select a function (Yes) or to cancel your selection (No). The changes are effective immediately. ▶ Press the Back key to close the menu. 6 720 811 136-15.1O Table 7 Favourite functions 6 720 818 009 (2015/07) Compress 3000 AW VOGEL NOOT & CLIMATE CONTROL SYSTEMS...
  • Page 9: Maintenance

    Moisture can form under the heat pump (outside) due to condensate not falling into the condensation catch pan. This is normal and no special action is required. Compress 3000 AW 6 720 818 009 (2015/07) VOGEL NOOT &...
  • Page 10: Pressure Switch And Overheating Protection

    ▶ Firmly push the button at the overheating protection. ▶ Reinsert the front panel Resetting the overheating protection at the indoor unit AWES: ▶ Consult the system installer. 6 720 818 009 (2015/07) Compress 3000 AW VOGEL NOOT & CLIMATE CONTROL SYSTEMS...
  • Page 11 Maintenance | 11 6 720 810 353-10.1I Fig. 7 Indoor unit AWMS/AWM solar Resetting the overheating protection Particle filter Pressure gauge Compress 3000 AW 6 720 818 009 (2015/07) VOGEL NOOT & CLIMATE CONTROL SYSTEMS...
  • Page 12: Internet Connection Via Integrated Ip Module

    Mac: ___ ___ - ___ ___ - ___ ___ - ___ ___ - ___ ___ - ___ ___ access and a router with unassigned RJ45 output are required. This can lead to additional costs. The Bosch connect app is required to control the system using a Environment / disposal mobile phone and is available free of charge.
  • Page 13: Technical Terms

    Settings in the standard display and in the menu can only be changed if The part of the heating system that transports the heat from the heat the child lock (key lock) is switched off ( page 7). pump to the indoor unit. Compress 3000 AW 6 720 818 009 (2015/07) VOGEL NOOT &...
  • Page 14 DHW is available at the draw-off points (e.g. taps). This is a prerequisite for longer hot shower. Time program for the heating system This time program ensures automatic changeover between operating modes at defined switching times. 6 720 818 009 (2015/07) Compress 3000 AW VOGEL NOOT & CLIMATE CONTROL SYSTEMS...
  • Page 15 | 15 Notes Compress 3000 AW 6 720 818 009 (2015/07)
  • Page 16 8661 St. Barbara, Austria www.vogelundnoot.com/int/ KE KELIT NZ Ltd 0800 4 KEKELIT (0800 4 5353548) climatecontrol@kekelit.co.nz www.kekelit.co.nz CLIMATE CONTROL SYSTEMS...