Menu item
Description
Warning sound
If a buzzer has been installed a warning sound is
blocked
emitted as soon as an alarm occurs. The warning
sound can be suppressed at a settable time interval.
Reduced DHW
Setting for the reduced DHW mode. If [Yes] is set,
temp.
the DHW temperature is reduced if there are a
compressor fault. The function is used to reduce the
use of the auxiliary heater.
DHW temp.
Correction of the DHW temperature displayed by
correction
the user interface by up to ± 10 °C.
Time correction Time correction of the internal clock of the user
interface in s/week.
Standard display Settings for the display of additional temperatures in
the standard display.
Internet
Reset the personal password for the Internet
password
connection (only available if a communication
module is installed). The next time you log in, e.g.
using an App, you will automatically be prompted to
assign a new password.
Internet
Make settings for the Internet connection (only
available if a communication module is installed).
• [Establish connection]
– [Pairing-Status]
– [Activate hotspot]
– [Activate WPS]
• [Terminate connection]
– [Connected network]
– [Terminate connection]
Low-noise
If activated the heat pump will run in reduced sound
operation
operation during the set time period.
• [Low-noise operation of]: set the start time for
the low noise operation.
• [Low-noise operation until]: set the stop time for
the low noise operation.
• [Min. outside temp.]: Below this outdoor
temperature the heat pump switches over to
normal operation.
Reset
Reset all settings to the values set at commissioning.
Table 19 General Settings
3.4

Calling up information about the system

The current system values and the active operating conditions can be
displayed easily via the info menu. No changes can be made in this menu.
To open the info menu:
▶ Press the info key in the standard display.
Menu: Sum./winter changeover
Menu item
Description
Heating/cooling
Currently valid operating mode in the selected
mode
heating circuit.
Set room temp.
The desired room temperature that is currently valid
in the selected heating circuit:
• In automatic mode, this can change several times
a day, if necessary.
• In normal operation, it is always constant.
Measured room
Currently measured room temperature in the
temp.
selected heating circuit
Measured flow
Currently measured flow temperature in the
temp.
selected heating circuit
Table 20 Information about the heating
Compress 7001i/7400i AW AWE – 6721835320 (2021/09)
Menu: DHW
Menu item
Description
Set temp.
Desired DHW temperature.
Measured temp. Currently measured DHW temperature.
Table 21 Information about DHW
Menu: Ventilation
Menu item
Description
Op. mode
Currently selected operating mode and ventilation level
Outside temperature Display of Outside temperature
Supply air temp.
Display of supply air temperature
Ex.air temp.
Display of extract air temperature
Exhaust air temp.
Display of exhaust air temperature
Reheat supp.air temp. Display of supply air temperature from the re-heater
Ex.air humid.
Display of exhaust air humidity
Ex.air quality
Display of exhaust air quality
Humidity remote ctrl
Display of humidity in the installation room of the
remote control
Amb. air humid.
Display of ambient air humidity
Amb. air quality
Display of ambient air quality
Bypass
Display of bypass-settings
Rem. filter elapsed
Display of duration in days until the next filter change
time
Table 22 Information about the ventilation unit
Menu: Pool
Menu item
Description
Set pool
Desired pool temperature.
temperature
Current pool
Currently measured pool temperature.
temperature
Table 23 Information about pool
Menu: Operating data
Menu item
Description
Control
Hours run by the control since the heat pump was
operating hours
commissioned or since the last reset.
Aux. heater
Output of the electric booster heater since
energy cons.
commissioning or since the last reset.
Op. hours for
Hours run by the compressor in heating mode since
comp. heat.
commissioning or since the last reset.
Op. hours for
Hours run by the compressor in cooling mode since
comp. cool.
commissioning or since the last reset.
Op. hours for
Hours run by the compressor in DHW operation
comp. DHW
since commissioning or since the last reset.
Op. hours for
Hours run by the compressor in pool operation since
comp. pool
commissioning or since the last reset.
Number of
Number of compressor starts in heating mode since
heating starts
commissioning or since the last reset.
Number of
Number of compressor starts in cooling mode since
cooling starts
commissioning or since the last reset.
Number of DHW
Number of compressor starts in DHW operation
starts
since commissioning or since the last reset.
Number of pool
Number of compressor starts in pool operation since
starts
commissioning or since the last reset.
Table 24 Operation data
Operation
17