© National Instruments Corporation
E Series
DAQ Device
SCC-AO10
AO ( X )
AO GND
Figure 1. SCC-AO10 Connected to a Nonreferenced Load
E Series
DAQ Device
SCC-AO10
AO ( X )
AO GND
Figure 2. SCC-AO10 Connected to a Load with a High Common-Mode Voltage
Connecting Two SCC-AO10 Modules in Series
You can increase the maximum total output voltage to ±20 V by connecting
two SCC-AO10 modules in series. Plug the two modules into sockets J17
and J18 of the SC-2345, and wire the modules to a load as shown in
Figure 3.
I
I
5
SCC-AO10 Isolated Analog Output Module User Guide
3
2
Load
1
3
2
Load
1