Maintenance

Important Note
For optimum maintenance periodically remove the tap from the installation, inspect and
clean the strainer. If debris is present in the strainer it is recommended to flush the water
supply pipework.
O Ring Kit service
Service and maintenance must be undertaken by a suitably qualified plumber. Warranty may be
void if damage to internal components occurs during this procedure.
First start by
shutting off the main water supply.
1.
Remove the indicator (1)
2.
Undo the screw (2) and remove the
handle (3)
3.
Undo the head valve (7) and remove
the cartridge (4)
For optimum operational life, the installation of a PRV set to 350kPa is recommended
10
No.
Description
01
Indicator
02
Screw
03
Handle
04
Cartridge
05
Body
06
Stem
07
Head Valve
08
U Cup
09
O-Ring
10
Crown Ring
11
O-Ring
12
Stopper
13
U Cup
Note
The O – Ring Service Kit
contains #8, #9, #11 and
#13
Qty
1
1
1
1
1
1
1
1
1
1
1
1
1