Combustion/Exhaust Blower Replacement - Quadra-Fire TREKKER-CSB Owner's Manual

Trekker free standing pellet
Hide thumbs Also See for TREKKER-CSB:
Table of Contents

Advertisement

TREKKER
I . Combustion/Exhaust Blower Replacement
1. Follow the proper shut down procedures.
2. Remove the right side panel by loosening the 2 screws
using a Phillips head screw driver or wrench. Figure
20.1.
3. It is not necessary or recommended to remove the hous-
ing to replace or service the combustion blower. You
only need to remove the motor and impeller.
4. Disconnect the wire from the control board connection
and hall effect switch/housing.
5. Using an 7mm socket wrench or nut driver, loosen the
nuts securing the motor and impeller to the housing.
6. Holding the motor, rotate the mounting plate count-
er-clockwise and remove motor and impeller.
7. If the gasket between housing and motor is damaged it
will have to be replaced. A gasket is included with the
replacement blower.
8. Re-install in reverse order.
Figure 20.1
20
7080-166B
April 18, 2018