166 Safety functions

FSO boot behavior with SLS active

When the safe speed estimate is in use, the following boot behavior exists.
During FSO module boot, the FSO module has no valid speed data and thus a very
high initialization value for motor speed is assumed for internal FSO usage. If an SLS
function or variable SLS function is active during FSO reboot and parameter
is configured so that Modoff delay time or Monitoring active is selected, the FSO will
prevent the drive from restarting until the
1
2
Step
Description
1
SLS request is active during FSO boot.
2
FSO module is rebooted.
3
STO.14
has elapsed, STO acknowledgement is possible, and SLS indication is
activated.
Note: STO acknowledgement is not possible until
to acknowledge STO before
be restarted.
STO.14
3
STO.14
delay time counter is started.
STO.14
delay has elapsed,
delay time has elapsed.
SLS request
FSO boot
SLS ok
STO
STO.14 delay
Time
STO.14
delay has elapsed. If you try
STO.14
delay time counter will
SLSx.05