ABB FSO-21 User Manual page 405

Safety functions module
Hide thumbs Also See for FSO-21:
Table of Contents

Advertisement

Index
Name/Value
200.223 Safety fieldbus
adapter slot
FBA A
FBA B
200.231 FSE 3X act and par
version
Disabled
Version 1
200.232 Number of encoders Sets the number of encoders that are
Single encoder CH1
200.254 CRC of the
configuration
0...65535
FSOGEN
FSOGEN.01 FSO general
settings version
Version 1
FSOGEN.11 Stop completed
output
None
DO X113:7 & X114:7 Redundant output X113:7 & X114:7
DO X113:8 & X114:8 Redundant output X113:8 & X114:8
Description
Sets the slot in which the safety fieldbus
adapter is installed.
Note: The slots on the drive control board
are defined by drive parameters 50.01 (FBA
A) and 50.31 (FBA B). See the drive
firmware manual.
The safety fieldbus adapter is in slot FBA A.
The safety fieldbus adapter is in slot FBA B.
Activates or deactivates the FSE-3x encoder
interface and shows the version of the
encoder parameter groups (includes groups
91
Enc module settings
configuration).
Deactivates the FSE-3x encoder interface.
Activates the FSE-3x encoder interface.
connected to the FSE module and, in the
single encoder case, also the channel that it
is connected to.
Note: ACS880 primary control program,
version 2.21 supports only one safety pulse
encoder.
Note: DCS880 firmware version 2.07
supports only one safety pulse encoder.
This parameter is read-only.
Shows the FSO configuration checksum.
Checksum
General FSO parameters
Shows the version of the FSO general
parameter group (includes parameter
groups
FSOGEN
and
parameters SLSx.02, SLSx.03, SLSx.04,
SARx.02).
Version 1.
Sets the digital output that indicates the
completion of any stop function. Active when
the FSO module has completed the STO,
SSE or SS1 function.
No input connected
Parameters 405
and 92
Encoder 1
SAFEIO
and
Factory
default
FBA A
Disabled
Single
encoder
CH1
0
Version 1
None

Advertisement

Table of Contents
loading

Table of Contents