Water Temperature Adjustment - Kohler K-1098 Installation Manual

Bath/shower faucet
Table of Contents

Advertisement

Available languages

Available languages

Setscrew
Valve
Stem

15. Water Temperature Adjustment

CAUTION: Risk of personal injury. The water temperature
should never be set above 120° F (49° C).
NOTE: Do not remove the O-ring and collar at this time. Removing
the O-ring and collar will change the factory setting for the
maximum water temperature.
If the handle and escutcheon assembly are installed, remove them
now.
Turn the valve clockwise to the full open position and let the hot
water run for several minutes. Position a thermometer in the
water stream and check the temperature.
For minor water temperature changes, adjust the setscrew, and
recheck the water temperature.
For major water temperature changes, remove the O-ring and
collar from the valve stem. Slowly rotate the valve stem until the
desired maximum water temperature is reached.
Reinstall the collar on the valve stem with the setscrew against
the side of the tab.
Reinstall the O-ring and rotate the valve stem counterclockwise to
shut the water off.
Recheck the water temperature.
Complete the information on the valve label (if supplied).
Kohler Co.
Tab
Collar
Valve
Label
O-Ring
19
114542-2-BC

Advertisement

Table of Contents
loading

This manual is also suitable for:

K-1099

Table of Contents